--- prog/pwm/fancontrol 2012-11-07 03:26:37.000000000 +0200
+++ prog/pwm/fancontrol 2013-03-22 18:15:00.566696011 +0200
@@ -297,7 +297,7 @@
cd $DIR
# Check for configuration change
-if [ "$DIR" != "/" ] && [ -z "$DEVPATH" -o -z "$DEVNAME" ]
+if [[ "$DIR" != "/" && ( -z "$DEVPATH" || -z "$DEVNAME" ) ]]
then
echo "Configuration is too old, please run pwmconfig again" >&2
exit 1
@@ -337,7 +337,7 @@
# It didn't work, try pwmN_enable=1 pwmN=255
echo 1 > $ENABLE 2> /dev/null
echo $MAX > $1
- if [ `cat $ENABLE` -eq 1 -a `cat $1` -ge 190 ]
+ if [ `cat $ENABLE` -eq 1 ] && [ `cat $1` -ge 190 ]
then
# Success
return 0
@@ -469,7 +469,7 @@
else
# calculate the new value from temperature and settings
pwmval="(${tval}-${mint})*(${maxpwm}-${minso})/(${maxt}-${mint})+${minso}"
- if [ $pwmpval -eq 0 -o $min_fanval -eq 0 ]
+ if [ $pwmpval -eq 0 ] || [ $min_fanval -eq 0 ]
then # if fan was stopped start it using a safe value
echo $minsa > $pwmo
# Sleep while still handling signals
|